原装进口e定做

    原装进口e定做

  • 1390
  • 产品价格:9000.00 元/套
  • 发货地址:北京怀柔怀柔 包装说明:不限
  • 产品数量:9999.00 套产品规格:不限
  • 信息编号:153561624公司编号:14298022
  • 潘海荣 微信 150204831..
  • 进入店铺 在线咨询 QQ咨询 在线询价
    相关产品:


北京恒瑞华宇科技有限公司

EPS消防应急电源的概述,什么是EPS应急电源
EPS消防应急电源的概述,什么是EPS消防应急电源
EPS emergency power supply overview, what is EPS Emergency Power Supply

EPS是应急电源系统-Emergency Power Supply的英文缩写
EPS is the emergency power system-Emergency Power Supply abbreviation

EPS应急电源[1]是根据消防设施、应急照明、事故照明等一级负荷供电设备需要而组成的电源设备。产品由互投装置、自动充电机、逆变器及蓄电池组等组成。在交流电网正常时逆变器不工作,经过互投装置给重要负载供电。当交流电网断电后,互投装置将会立即投切至逆变电源供电。当皇冠网电网电压恢复时,互投装置将会投切至交流电网供电。
EPS Emergency Power Supply [1] is based on fire-fighting facilities, emergency lighting, emergency lighting and other powered equipment needs a load consisting of power supplies. Products from each switch device, automatic charging machine, inverters and batteries and other components. In the normal AC power inverter does not work, after each vote means a significant load. When the AC power grid, each switch device will immediately switching to the inverter power supply. When the grid voltage is restored, each switch device will be switching to the AC mains supply.

EPS消防应急电源的工作原理是什么样的?
EPS消防应急电源的工作原理是什么样的?
EPS emergency power supply works is what?

EPS应急电源采用单体逆变技术,集充电器、蓄电池、逆变器及控制器于一体。系统内部设计了电池检测、分路检测回路,其他主要部件的工作原理如图所示,智能化应急电源,采用后备式运行方式。
EPS emergency power supply with single inverter technology, set charger, battery, inverter and controller in one. Internal design of the battery testing system, shunt detection circuit, the other major component works as shown, intelligent emergency power supply, the use of back-up run.


(1)当市电正常时,由市电经过互投装置给重要负载供电,同时进行市电检测及蓄电池充电管理,然后再由电池组向逆变器提供直流能源。在这里,充电器是一个仅需向蓄电池组提供相当于10%蓄电池组容量(Ah)的充电电流的小功率直流电源,它并不具备直接向逆变器提供直流电源的能力。此时,市电经由EPS的交流旁路和转换开关所组成的供电系统向用户的各种应急负载供电。与此同时,在EPS的逻辑控制板的调控下,逆变器停止工作处于自动关机状态。在此条件下,用户负载实际使用的电源是来自电网的市电,因此,EPS应急电源也是通常说的一直工作在睡眠状态,可以有效的达到节能的效果。
(1) When the mains is normal, the municipal electric device after each vote to the critical load power mains detection and simultaneous battery charging management, and then to the inverter from the battery pack to provide DC power. Here, the charger to the battery pack is provided a distance of 10% battery capacity (Ah) of the charging current of the small-power DC power supply, it does not have direct provide DC power to the inverter capacity. In this case, the exchange of electricity via EPS bypass and switch the power supply system consisting of the user's various emergency loads. At the same time, the logic of the EPS under the control panel, the inverter stops working in automatic shutdown state. In this condition, the user loads the actual use of power is electricity from the grid, thus, EPS emergency power supply is often said that has been working in the sleep state, can effectively achieve the energy saving effect.

(2)当市电供电中断或市电电压**限(±15%或±20%额定输入电压)时,互投装置将立即投切至逆变器供电,在电池组所提供的直流能源的支持下,此时,用户负载所使用的电源是通过EPS的逆变器转换的交流电源,而不是来自市电。
(2) when the mains power supply is interrupted or mains voltage gauge (± 15% or ± 20% rated input voltage) when each switch device will immediately switching to the inverter, the battery pack provided by the DC energy support, at this time, the user load power used by the EPS inverter to convert AC power, rather than from the mains.

(3)当市电电压恢复正常工作时,EPS的控制中心发出信号对逆变器执行自动关机操作, 同时还通过它的转换开关执行从逆变器供电向交流旁路供电的切换操作。此后,EPS在经交流旁路供电通路向负载提供市电的同时,还通过充电器向电池组充电。
(3) When the mains voltage returns to normal operation, EPS control center sends **s to the inverter perform automatic shutdown, but also through its switch execution from the inverter to the AC bypass switch operation. Thereafter, EPS in the bypass passage through AC mains to the load, it is also through the charger to charge the battery pack.

(4)除用于应急照明系统外,其中三相智能化变频应急电源主要是为一级负荷中的电动机提供一种可变频的应急电源系统,该产品方便解决了电动机的应急供电及其启动过程中对供电设备的冲击影响。智能化应急电源可接受消防联动信号、建筑智能总线信号控制,并可设定**级,防止越级控制。
(4) Except for the emergency lighting systems, intelligent three-phase inverter which is mainly for an emergency power load of the motor to provide an emergency power system frequency, the product easy to solve the emergency power supply and motor start process of the power supply equipment shocks. Intelligent emergency power acceptable fire linkage **s, building intelligent bus ** control, and set priorities to prevent leapfrog control.

UPS和EPS的功能区别
EPS和UPS都具备市电旁路和逆变电路,但是EPS只具有持续供电功能,对逆变切换时间要求不高,目前大部分EPS还具备蓄电池单体检测功能。EPS在市电中断后才进行逆变输出,电脑利用率高。
而UPS一般强调其三大功能:对市电进行稳频和稳压处理;对切换时间要求较高的设备供电;净化市电。日常着重整流和逆变的双变换电路供电,电能利用率不高。但是UPS不仅仅是在断电时逆变供电,还可以在市电出现电压偏差大、浪涌等异常情况时提供稳定的电力输出,这是EPS所不具备的。
3)UPS和EPS在应用范围的不同
EPS主要用于消防类负荷以及一些对切换时间要求不高,但需要持续供电的设备。
UPS主要用于计算机、数字信息系统等对供电质量要求较高的负载。

产品原理
SKEPS系列单相EPS应急电源,是为建筑物内紧急疏散照明或重要用电设备提供集中供电的应电电源设备。
当市电正常时,由市电经过互投装置给负载供电,同时充电器给备用电池进行智能充电。当市电断电,或**过正常电压的20%时,由控制器提供逆变信号,启动逆变电源,同时互投装置将立即投切至逆变电源输出,继续提供正弦波交流电,当市电电压正常后,应急电源将自动恢复电网供电。
产品特点
1、采用集中模式、*特殊灯具;
2、双路电源自动切换,可靠性高;
3、寿合长,主机寿命20年以上;
4、采用CPU控制,保证各动作点准确;
5、LED显示和声音告警,工作状态一目了然;
6、具有过压、欠压、过温、过流、短路等保护功能;
7、智能电池充电管理功能,可实现均浮充自动转换,有效延长电池寿命;
8、自动监控电池工作状态,具有电池充放自动保护;
9、模块化结构设计,维护方便。
-/gjdjjf/-

欢迎来到北京恒瑞华宇科技有限公司网站,我公司位于拥有6项*遗产,拥有文化遗产项目数较多的城市,一座有着三千余年建城历史、八百六十余年建都史的历史文化名城,拥有众多历史名胜古迹和人文景观的中国“八大古都”之一 —北京。 具体地址是北京怀柔怀柔迎宾中路36号二层23904室,联系人是潘海荣。
联系电话是4008765216, 主要经营北京恒瑞华宇科技有限公司是一家理士蓄电池总代理、圣阳蓄电池总代理、APC UPS电源总代理、北京施耐德UPS总代理、北京消防电源生产厂家。从事 蓄电池,UPS电源设备的销售、安装和服务的一个整体机房集成工程。 。
单位注册资金单位注册资金人民币 100 万元以下。

  • 供应商更多产品推荐
  • 关于八方 | 招贤纳士八方币招商合作网站地图免费注册商业广告友情链接八方业务联系我们汇款方式投诉举报
    八方资源网联盟网站: 八方资源网国际站 粤ICP备10089450号-8 - 经营许可证编号:粤B2-20130562 软件企业认定:深R-2013-2017 软件产品登记:深DGY-2013-3594 著作权登记:2013SR134025
    互联网药品信息服务资格证书:(粤)--非经营性--2013--0176
    粤公网安备 44030602000281号